Volume | Length | Width | Height | |
46 m3 | 12957 mm | 2550 mm | 3780 mm | |
50 m3 | 13940 mm | 2550 mm | 3780 mm | |
54 m3 | 14940 mm | 2550 mm | 3780 mm |
Design Conditions (LNG SEMI TRAILER) | ||
DESIGN CODE | : | EN 13530 / ADR |
WORKING PRESSURE | : | 6 bar |
DESIGN PRESSURE | : | 7 bar |
TEST PRESSURE | : | 9,1 bar |
DESIGN TEMPERATURE | : | +50°C / -196°C |
INNER TANK MATERIAL | : | EN 10028-7 Compliant with |
OUTER TANK MATERIAL | : | EN10025-2 Compliant with |
RADIOGRAPHIC CONTROL | : | EN 13530 Compliant with |
LIQUID PENETRANT TEST | : | EN 13530 Compliant with |
INSULATION | : | Multilayer Insulation Oxygen service cleaning is carried out in accordance with EN 12300. |
Volume |
Length | Width | Height | |
LAR | 19 m3 | 10050 mm | 2550 mm | 3500 mm |
LOX | 24 m3 | 10550 mm | 2550 mm | 3500 mm |
LIN | 33 m3 | 10600 mm | 2550 mm | 3750 mm |
Design Conditions (LIN - LOX - LAR SEMI TRAILER) | ||
DESIGN CODE | : | EN 13530 / ADR |
ÇALIŞMA BASINCI | : | 3-16 bar |
WORKING PRESSURE | : | 4-17 bar |
TEST BASINCI | : | 5,2-22,1 bar |
DESIGN PRESSURE | : | +50°C / -196°C |
TEST PRESSURE | : | EN 10028-7’e uygun |
OUTER TANK MATERIAL | : | EN10025-2 Conforms |
RADIOGRAPHIC CONTROLL | : | EN 13530 In accordance with |
LIQUID PENETRANT TEST | : | EN 13530 In accordance with |
INSULATION | : | Multilayer Insulation Oxygen service cleaning is carried out in accordance with EN 12300. |